Digitrax DCS210+ Option Switches
Summary: This table contains the option switches for a Digitrax DCS210+ DCC Command Station
This table lists the default state of the option switches, as found using the JMRI Configure Command Station tool.
DCS210+ Option Switch Listing
Note: At the time this table was published, Digitrax does not publish a comprehensive list of option switches for the DCS210+. This table may contain errors as there is no validation available.
The user manual only publishes values for OpSw #2, #3, and #40. It refers the user to the Digitrax website for further information.
If an option is labelled reserved, do not change it.
DCS210+ Option Switches | ||
---|---|---|
Options are active when Option Switch is CLOSED | ||
Switch | Default | Purpose |
1 | Thrown | Reserved |
2 | Thrown | DCS210+ to operate as a booster, not as a command station |
3 | Thrown | Booster is auto reversing |
4 | Thrown | Reserved |
5 | Thrown | Reserved |
6 | Thrown | Do not check for a decoder before programming |
7 | Thrown | Reserved |
8 | Thrown | Reserved |
9 | Closed | Reserved |
10 | Closed | Reserved |
11 | Thrown | Reserved |
12 | Thrown | Reserved |
13 | Thrown | Increase loco purge time to 600 seconds |
14 | Thrown | Disable loco address purging |
15 | Thrown | Purge forces loco speed to zero |
16 | Thrown | Reserved |
17 | Thrown | Automatic Advanced Consists disabled |
18 | Thrown | Extended booster short circuit shutdown time |
19 | Thrown | Reserved |
20 | Thrown | Disable Analog operations (Address 00) |
21 | Closed | Global default for new locomotive: FX |
22 | Closed | Global default for new locomotive: 28 speed steps |
23 | Thrown | Global default for new locomotive: 14 speed steps |
24 | Thrown | Reserved |
25 | Thrown | Disable route echo on LocoNet |
26 | Closed | Routes enabled |
27 | Thrown | Bushby Bit |
28 | Thrown | Do not send interrogate messages on power up |
29 | Thrown | Reserved |
30 | Thrown | Reserved |
31 | Thrown | Fast route/switch output when not in trinary mode |
32 | Thrown | Reserved |
33 | Closed | Restore prior state of track power upon power up |
34 | Thrown | Allow track to power up in Run state |
35 | Thrown | Disable Loco Reset Button |
36 | Thrown | Clear all multifunction decoder info and consists |
37 | Thrown | Clear all routes |
38 | Thrown | Loco Reset initiates "Slot Zeroing" |
39 | Thrown | Clear all internal memory states |
40 | Thrown | Reset all multifunction decoder info, consists, routes and Voltage Trim to Factory Default |
41 | Thrown | Diagnostic click when LocoNet commands are received or Routes are input |
42 | Thrown | Disable two beeps when loco address is purged |
43 | Thrown | Disable LocoNet update of track status. |
44 | Closed | Reserved |
45 | Thrown | Disable reply for switch state request |
46 | Thrown | Reserved |
47 | Thrown | Program track is brake generator |
48 | Thrown | Reserved |
49 | Thrown | Allow IDLE power stat |
50 | Thrown | Reserved |
51 | Thrown | Reserved |
52 | Thrown | Reserved |
53 | Thrown | Reserved |
54 | Thrown | Last recall speed at POR, not Zero |
55 | Thrown | Reserved |
56 | Thrown | Reserved |
57 | Thrown | Reserved |
58 | Closed | Reserved |
59 | Thrown | Reserved |
60 | Closed | Reserved |
61 | Closed | Reserved |
62 | Thrown | Reserved |
63 | Thrown | Reserved |
64 | Thrown | Reserved |
65 | Closed | Reserved |
66 | Thrown | Do not use Advanced Commands |
67 | Thrown | Reserved |
68 | Thrown | Reserved |
69 | Closed | Reserved |
70 | Thrown | Disable BB7F check for other command stations |
71 | Thrown | No external command station disable |
72 | Thrown | Reserved |
73 | Thrown | Reserved |
74 | Thrown | Reserved |
75 | Thrown | Disable Program Track pre-charge |
76 | Thrown | Reserved |
77 | Thrown | After D5 commands lockout legacy SPD/fns etc. |
78 | Thrown | Send ACK on normal switch commands |
DCCWiki.com |
Setting an Option Switch
This proces can be done using the following methods:
- Throttle
- JMRI
Throttle
- Set the MODE switch to center OP position. The PWR and PROG LEDs will pulse alternately.
- Connect a LocoNet throttle and select its switch control mode.
- Select the switch (Option Switch) number, then set T/Thrown or C/closed to modify the OPSW as needed.
- Return MODE switch to RUN position when complete
JMRI
As the DCS210+ features a USB port, it can be connected directly to a computer running JMRI software.
JMRI can configure a command station and offers two methods. Consult the JMRI help pages for details.